Pratheep,
Go to SE16N, table NACE, give your output type and then execute.
Please paste that screenshot here, especially check printer name.
TW
Message was edited by: TW Typewriter
Pratheep,
Go to SE16N, table NACE, give your output type and then execute.
Please paste that screenshot here, especially check printer name.
TW
Message was edited by: TW Typewriter
Hi Alice,
Got any pointer for the issue ?
I am also facing the same problem..!!
Thanking You All..!!
Pratheep,
Please delete this condition record and create again. and then test.
In record input printer name.
TW
Hi Rohini,
In my opinion please go for BTE 2310 available in the standard program.
Similarly you can change the Email body, subject,etc...
Regards,
Hari
Hi,
I would suggest you try to add at the begining of your smartform a Node of type "Program Lines" and call the function Module "SSFCOMP_PRINT_CONTROL". Pass the to it the value TRY01, TRY02...or TRY10, etc.
hope this will help!
Bahjat
Hi,
I need the table names and fields to provide Develepers.
Appreciate for quick response.
Thanks
You can find table names and fields name easily. Don't expect spoon feeding from this forum and please put some efforts. Search in goole or simply check table and filed names by pressing F1 and technical information.
Thank$
Hi Ankita,
Change the data type of the short text and try .
Thanks & Regards,
Pramodh.M
I was facing a similar issue.
Reactivating smartform using report RFRECPSFTLGEN has fixed my problem.
Original Thread:
This fixed my problem. Thanks a lot!
Hi Expert,
I have Define two Printer in SPAD,
1) LOCL : is using SWIN as device TYPE
2) ZRIC: RICOH Device type.
Now, when i am testing smartform output on Printer then I can able to print on same Printer because LOCL & ZRIC is same Printer.
What are pros & cons of using both Printer? I think, I may not able use LOCL for background job Printing .
Thanks a lot.
I have changed the access sequence to sales org/Billing type
which is working fine
Thanks for the support friends
Regards,
Pratheep
Pratheep,
This is interesting! The condition table (access) with only sales organization should have also worked. If you delete the configuration and redo it, then it will work.
There are business scenarios where output is needed when a document is created with the valid sales organization, so it should work.
Glad to know that you have done some creative changes and then the output works successfully.
TW
Hi Vipin,
the PROs are that you are able to test your form definition using two different device types (btw SWINCF would be better than SWIN, because it supports Unicode): SWIN and an unnamed Ricoh device type which probably "speaks" PCL5 or PostScript. Your output will look slightly different because different fonts are available for both device types.
You may possibly construct your form in such a way that it works on both types of device types.
Regards,
Alex
Hello,
Frontend printing (access method G or F) cannot be used for back ground job printing.
Best regards,
Yiming
Hi, Colleagues
Does everyone know how to create Drilldown Report for Internal Order? I've just investigated that it is possible to create Drilldown Report for Productive Order, via tkod KKO0. Unfortunately, it does not work with Internal Order.
Hi SAP Gurus,
I can't solve problem with printing using frontend (SAPlpd). In our company we are using frontent print (access method F). All employees print without problem, but I can't print from one notebook (Windows 8.1).
Each print finish with status INCORRECT and SAPlpd doesn´t start!
Complete message: Connection closed after (protocol) error (RC=1)
I tried:
- reinstall notebook
- few version of SAPGui
- change setting of firewall, try print with turn off firewall
- use old version of SAPlpd
- look in path for log files (print options editor of SAPGui), this folder is empty
- look in path for temporary files (print options editor of SAPGui), this folder is empty
I read few discussions, but I can´t find any solution.
Any ideas?
Thanks
Lukas
Hi Gurus,
I am facing a issue with Smart form DDIC field in SFSY structure- SAP Smart Forms: System Fields,
some of the field data types need to be changed form INT4 to CHAR in ECC system on technical upgrade.
kindly help me on this.
Regards,
Lakshmi Narayanan v
Thanks a lot Alexander for your reply. Yesterday, I understood that if i am using LOCL printer and printing a barcode in output, then BARCODE.DLL should be available on my machine.